spirasarco product APT10 and APT14 automatic trap valve pump Spirasar valve UK sales product selection offer
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

spirasarco

  • APT10 and APT14 Automatic Trap Pumps spirasarco Spirasarco
APT10 and APT14 Automatic Trap Pumps spirasarco Spirasarco

APT10 and APT14 Automatic Trap Pumps spirasarco Spirasarco

  • spirasarco Product selection Product quotation Technical support After-sales service
  • Spirax Sarco ball valve, check valve, air exhaust valve, pressure relief valve, vacuum breaker, vapor-water separator
  • spirasarco filter pressure gauge spirasarco steam trap spirasarco electric pump
  • British valve Boiler control system Steam control valve Plumbing equipment Soda separator Filter Plunger valve Pressure reducing valve British ball valve spirasarco British exhaust valve
  • Product description: SpiraxSarco Valve Co., Ltd. provides you with imported steam traps, bellows globe valves, filters, pressure reducing valves, ball valves, check valves, safety valves, regulating valves, float ball tra
  • INQUIRY
APT10 and APT14 Automatic Trap Pump
The main difference between Spirax Sarco APT10 and APT14 automatic trap pumps is that the APT10 automatic trap pump has only one ball, while the APT14 automatic trap has two floats. The diameter of the automatic trap pump is also larger.
Some products and services are only available in certain regions.
Drainage and recovery of condensate from Spirax Sarco APT10 and APT14 trap valves
For most steam-using equipment, the condensed water must be drained as soon as it is generated, otherwise the heat exchange efficiency of the system will be affected, the possibility of water hammer will be increased, and the accumulated water may cause corrosion when the system is stopped. Therefore, the effective discharge of condensate is a necessary condition to improve the performance of the steam system and extend the service life of the equipment. It is generally believed that the steam pressure in the heat exchanger is sufficient to discharge the condensed water out of the heat exchanger. However, there are two cases where the condensate will not be effectively discharged:
● High back pressure of condensate
● Low steam pressure in heat exchanger
In either case, there is not enough pressure differential to remove condensate from
The trap is drained from the heat exchanger to the recovery pipe.
Water accumulation in heat exchanger
Drainage of Condensate from Spirax Sarco APT10 and APT14 Trap Pumps
Compact
Only 0.2m installation height is required from the base of the automatic trap pump
Process equipment that can be easily installed in a low position
Drain condensate in all cases, even under vacuum
No electricity needed to drive the condensate and consume almost no energy-suitable for hazardous areas
High displacement
Designed to meet A.D. Merkblatter / ASME VIII standards, European Pressure Equipment Directive 97/23 / EC, ATEX Directive 94/9 / EC, technical support, knowledge and service from Spirax Sarco worldwide
Pump body and cover are also nickel plated (ENP coating)