Imported pneumatic fluorine-lined control valve straight single-seat ball valve YLOK product
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

YLOK

  • Imported pneumatic fluorine-lined control valve YLOK
Imported pneumatic fluorine-lined control valve YLOK

Imported pneumatic fluorine-lined control valve YLOK

  • Imported solenoid valve Imported regulating valve Water valve Butterfly valve Gate valve Globe valve Check valve Ball valve
  • Stopcock safety valve Diaphragm valve Needle valve Steam trap Pressure reducing valve Exhaust valve Filter
  • Control valve High pressure bypass control Low pressure bypass control valve Minimum flow valve and actuator
  • It is widely used in water treatment, environmental protection, medical treatment, petroleum, chemical industry, metallurgy, light industry and other industrial sectors and urban heating and heating s
  • Product description: YLOK imported pneumatic film fluorine-lined single-seat control valve. The inner wall and inner components of the valve in contact with fluid adopt high-pressure injection molding process, and are lin
  • INQUIRY

Imported pneumatic fluorine lined control valve
Imported pneumatic fluorine lined control valve product overview
  YLOK imported pneumatic film fluorine-lined single-seat control valve. The inner wall and inner components of the valve in contact with fluid adopt high-pressure injection molding process, and are lined with corrosion-resistant and aging-resistant polyfluoroethylene propylene (F46). It is sealed with PTFE bellows. It is widely used for the control of strong corrosive media such as acids and alkalis and toxic and volatile gases and liquids.
Features of imported pneumatic fluorine-lined film regulating valve
1. Corrosion resistance: Almost able to withstand the corrosion of all media (including concentrated nitric acid and aqua regia).
2. Good sealing performance: double sealing with bellows and packing to ensure no external leakage.
3. Small leakage: Because the valve core and valve seat adopt soft sealing, the leakage is low.
4. Equipped with HA actuator, with large output force and compact structure.
Some technical parameters of imported pneumatic fluorine-lined control valve (more technical parameters and information are welcome to call for request)
Type: Through single-seat ball valve
Nominal diameter: G3/4", 15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300mm
Nominal pressure: PN1.6MPa, PN2.5Mpa or ANSI 150LB
Flange standard: RF
Material: ZG230-450 lined with F46
Upper valve cover: -40~+180℃
Gland type: bolt compression type
Packing: V-shaped PTFE packing
Spool type: single seat plunger spool
Flow characteristics: linear characteristics and equal percentage characteristics
Spool material: 2Cr13 lining F46
Seat material: 2Cr13 lining F46
Bellows material: PTFE
Valve action type: air-to-close type (B) — valve position is open (FO) when air is lost; air-open type (K) — valve position is closed (FC) when air is lost
Accessories: limiter, air filter pressure reducer, retaining valve, travel switch, valve position transmitter, handwheel mechanism, etc.
Leakage: less than 0.01% of the rated capacity of the valve, in line with ANSI B16.104-1976 Class IV
Backlash: with positioner less than 1% of full stroke
Basic error: less than ±1% of full stroke with positioner
Adjustable range: 30:1
Actuator parameters:
Type: ZHA/B multi-spring diaphragm actuator
Membrane material: ethylene propylene rubber with nylon cloth, rubber with nylon cloth
Spring range: 20~100, 80~240KPa
Air supply pressure: 140~400KPa
Air source interface: internal thread M16X1.25