Imported electromagnetic shut-off valve Regus product British Regus Imported steam trap Pressure reducing valve Ball valve Solenoid valve Safety valve Gate valve Globe valve Butterfly valve Pneumatic angle seat valve Needle valve Check valve, regulating valve Filter
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

Regus

  • Regus Regis imported electromagnetic shut-off valve
Regus Regis imported electromagnetic shut-off valve

Regus Regis imported electromagnetic shut-off valve

  • The unique ability of Regus Valves in the miniaturization and engineering expertise to keep the company at the forefront of fluid control technology
  • British Regus valve products are widely used in aerospace, electrical equipment, petroleum exploration, medical, scientific instruments
  • Imported steam trap, imported pressure reducing valve, imported ball valve, imported solenoid valve, imported safety valve, imported gate valve, imported globe valve, imported butterfly valve, importe
  • Product description: Imported electromagnetic shut-off valve Regus product British Regus Imported steam trap Pressure reducing valve Ball valve Solenoid valve Safety valve Gate valve Globe valve Butterfly valve Pneumatic
  • INQUIRY
Name: Imported electromagnetic shut-off valve Model: Regus Caliber: 1/2" -20" Pressure: PN16 Material: WCB, 304, 316

British Regus Regus imported electromagnetic shut-off valve

British Regus Regus normally open series safety solenoid valve gas safety solenoid valve does not need power supply to keep the solenoid valve in normal working. When the gas leak alarm, only one 2 second instantaneous pulse power signal can quickly close the solenoid valve, saving electricity and safety. . The power supply can use DC 24V or AC 220V. When the valve is manually opened, the handle is pulled upwards to move the seal assembly up, so that the valve is in the open state; at the same time, the mechanical latching device performs the latching action to keep the valve in the open position. If the valve needs to be closed, the power of the valve closing coil should be turned on for a short time, and the electromagnetic attraction generated causes the mechanical latching device to be disengaged and locked, and the sealing assembly is reset downward by the elastic force of the return spring, so that the valve is closed. When there is no power supply, the manual closing valve handle can be used to replace the electromagnetic force to close the valve, and the action process is the same as the above electromagnetic force closing process.

British Regus Regus imported electromagnetic shut-off valve definition:

1. Connected to the flammable gas leak monitoring instrument. When the instrument detects the leakage of flammable gas, it automatically closes the main gas supply valve, cuts off the supply of gas, and stops the occurrence of a vicious accident in time.
2. Connect to the limit temperature (or pressure) safety controller of the thermal equipment. When the temperature or pressure of the detection point in the equipment exceeds the set limit value, the air supply valve is automatically closed quickly to stop the supply of fuel.
3. Connected to the central fire alarm system of the high-rise building. When the building is in danger, the gas supply in the building is automatically cut off to prevent the gas explosion.

4. Set the gas emergency shut-off valve in the gas supply pipe network of the city or factory, which can be centrally controlled in the central control room, remotely controlled, and emergencyly shut down the pipeline supply at the accident site.