Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

Buhrer

  • Imported flange low temperature gate valve Buhrer
Imported flange low temperature gate valve Buhrer

Imported flange low temperature gate valve Buhrer

  • Buhrer ball valve gate valve Buhrer butterfly valve globe valve
  • Buhrer solenoid valve Buhrer relief valve relief valve
  • Buhrer Trap Check Valve Buhrer Venting Valve Needle Valve
  • Buhrer angle seat valve diaphragm valve plug valve filter breathing valve flame arrester balance valve pump
  • Product description: Buhrer acting ball valve, Buhrer gate valve, Buhrer butterfly valve, stop valve, Buhrer control valve, solenoid valve, Buhrer safety valve, Buhrer pressure reducing valve, Buhrer drain valve, check va
  • INQUIRY
Product name: Imported flange low temperature gate valve Product model: Buhrer series
Drive method: manual Connection type: flange, welding
Structure: Wedge Seal structure: Hard seal
Pressure range: 150LB-2500LB Nominal diameter: DN15-500
Common materials: 304,316, etc.
Product introduction
The imported flanged cryogenic gate valve produced by Breer can be driven manually, flanged for welding, welded, and wedge-shaped for structural form, and hard-sealed for sealing structure. The pressure range is PN150LB-2500LB, and the nominal diameter is DN15. -500mm, material can be 304,316, etc. Because the valve is used in a very wide range, the same valve has different combinations in different situations and working conditions.
Product Details
The imported low temperature gate valve is suitable for valves with a medium temperature of -40 ℃ ~ -196 ℃ ~ -253 ℃. It is called a low temperature valve. It is mainly used for ethylene, liquefied natural gas equipment, natural gas LPG LNG storage tanks, receiving bases and satellite stations, air separation. Equipment, petrochemical tail gas separation equipment, liquid oxygen, liquid nitrogen, liquid argon, carbon dioxide cryogenic storage tanks and tank cars, pressure swing adsorption oxygen production and other devices. The output liquid low-temperature medium such as ethylene, liquid oxygen, liquid hydrogen, liquefied natural gas, and liquefied petroleum products are not only flammable and explosive, but also need to be gasified when the temperature rises, and the volume expands hundreds of times during gasification.
After many years of manufacturing in the United States, Buhrer has accumulated rich experience, from design, technology to manufacturing, which has become increasingly mature.It has developed and formed low temperature ball valves, low temperature gate valves, low temperature shut-off valves, low temperature safety valves, low temperature check valves, low temperature butterfly valves, and low temperature. Needle valve, low temperature throttle valve, low temperature pressure reducing valve series products.
Product specifications and design parameters of imported cryogenic gate valves
1. Pressure rating: 150, 300, 600Lb, 900LB, 1500LB, 2500LB (45MPa)
2. Valve diameter: 15 to 500 mm (1/2 to 20 ").
3. Connection form: flange type, welding type, thread.
4. Valve material: 304, 316, etc.
5. Working temperature: -46 ℃, -101 ℃, -196 ℃, -253 ℃
6. Applicable medium: LNG, ethylene, propylene, etc.
design feature:
1. Safety extension valve stem
2. The vent hole at the upstream end prevents abnormal pressure increase in the lumen
3. Extended valve cover
4. Anti-leakage packing
Test and inspection of imported cryogenic gate valve
The low temperature valve's main parts are processed at low temperature and each batch is sampled for low temperature impact test to ensure that the valve does not crack during low temperature working conditions and can withstand the impact of low temperature medium.
The following tests were performed on each valve:
1. Shell strength test at room temperature;
2. Seal test at room temperature and low pressure;
3. Normal temperature and low pressure seal test;
4. Airtightness test at low temperature (with upper seal);
5. Low temperature gas seal test, etc. to ensure that the entire low temperature valve meets the requirements of the standard;
6. The main parts of the low temperature valve are subjected to low temperature treatment and each batch is sampled for a low temperature impact test to ensure that the valve does not become brittle under low temperature conditions and can withstand the impact of low temperature media;
7. Low temperature (cryogenic) valves are subjected to low temperature treatment and impact tests in accordance with corresponding material specifications.
8. The electrostatic function is more powerful, and the on-resistance between the valve body and the valve stem or the internal parts and the valve body is less than 1 ohm.

CATEGORIES

CONTACT US

Contact: peng gong

Phone: 18918462396

Tel: 021-59718851

Email: kunage@126.com

Add: Lane 819, Qinghewan Road, Qingpu Industrial Park, Qingpu District, Shanghai

Scan the qr codeClose
the qr code