Introduction to the Use of One-way Valve in Maintenance of High and Low Temperature Test Box
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

Industry new

Introduction to the Use of One-way Valve in Maintenance of High and Low Temperature Test Box

When the high and low temperature test box fails, it is necessary to contact the manufacturer for door-to-door maintenance. If the equipment failures are incorrect and there are too many or too few cases, the maintenance personnel will take many tools, such as Freon cylinders, vacuum pumps, welding tools, toolkits and other maintenance tools, these tools can not be lacked, and their weight can not be underestimated. Therefore, it will bring unnecessary troubles to maintenance personnel, waste unnecessary time and thus reduce efficiency. For this kind of problem, we have to learn how to use the equipment one-way valve skillfully. Then someone will ask, how should the one-way valve be used in maintenance? The following will reveal for you:
Introduction of One-way Valve for High and Low Temperature Test Box
When purchasing a one-way valve, it is necessary to remove its spool and weld the one-way valve to the process pipe of the equipment. Make sure that the welding is leak-free and firm, then install the valve core. When vacuum is pumped, a fluorinated pipe with a thimble is needed to be connected, then the other end is connected with the corner valve, and then the table and the vacuum pump are connected. After the vacuum is exhausted, it is necessary to unload the vacuum pump, replace the fluorinated cylinder, remove the air from the second fluorinated pipe (corner valve), and then add fluorine.
When the test box is fluorinated, it is necessary to close the corner valve and unload the fluorinated cylinder. After the fluorinated pipe with thimble on the one-way valve is unloaded at the last step, the one-way valve can be sealed with a stuffy head.

With a one-way valve, when the high and low temperature test box appears "more fluorine" or "less fluorine", only need to remove the stuffy head, direct discharge of fluorine or fluoride from the valve core of the one-way valve. This also reduces the trouble for maintenance personnel, so that they can be lightly loaded into battle.