Liquid turbine flowmeter sensor maintenance instructions
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

Industry new

Liquid turbine flowmeter sensor maintenance instructions

The liquid turbine flow meter is a precision flow meter that can be used to measure the flow and total volume of liquids in conjunction with the corresponding flow meter. It is widely used in the measurement and control systems in the fields of petroleum, chemical, metallurgy and scientific research. Turbine flow sensors equipped with sanitary joints can be used in the pharmaceutical, food and other industries. Pay attention to the maintenance of the sensor in addition to the selection of the liquid turbine flowmeter.
    1. When using, keep the measured medium clean and free of impurities such as fibers and particles.
  2. When the liquid turbine flowmeter sensor is used, the sensor should be slowly filled with the medium and then the outlet valve should be opened (the valve should be installed at the back end of the flowmeter). The sensor is strictly prohibited from being impacted by high-speed fluid when it is in the mediumless state. .
    3. The maintenance period of the liquid turbine flowmeter sensor is generally half a year. When cleaning and cleaning, please be careful not to damage the parts inside the measuring chamber, especially the impeller. Please be optimistic about the positional relationship between the guide and the impeller during assembly.
   4. When the liquid turbine flowmeter sensor is not in use, the internal medium should be cleaned, and after drying, a protective cover is added at both ends of the sensor to prevent dust from entering, and then stored in a dry place.
   5. The used filter should be cleaned regularly. When not in use, the internal medium should be cleaned. As with the sensor, add a dust jacket and store it in a dry place.
   6. Before the sensor is installed, use the mouth to blow or hand the impeller to make it rotate quickly to see if there is any display. Install the sensor when there is display. If there is no display, check the relevant parts and troubleshoot.