Description of the parameters specified before the installation of the electromagnetic flowmeter
Electromagnetic flow
meter is widely used in industrial sewage, domestic water, sewage, petroleum, chemical, steel and other industrial sectors. It can measure acid-alkaline corrosive media. Electromagnetic flow
meter mainly consists of two parts:
sensor and converter. The principle of measurement Based on Faraday's law of electromagnetic induction, the main components of the
sensor are measuring tube, electrode, excitation
coil, iron core and yoke, and housing. The number of people who choose to use is because the electromagnetic flow
meter has accurate measurement and high stability. The correct selection and correct installation is the necessary condition for ensuring accurate measurement of the electromagnetic flow
meter.
The electromagnetic flow
meter must be clear of the following para
meters before installation:
1. Avoid strong vibration and strong corrosive places.
2. Keep away from strong magnetic field equipment.
3. The process does not allow the flow of the pipeline to be interrupted. When installing the flow
meter, a shut-off valve and a bypass line should be added.
4, the upstream of the flow
meter sensor should also have a certain straight pipe section, generally in 5D~10D.
5, can be installed horizontally, vertically and obliquely, but to ensure that the measuring tube is coaxial with the process pipe, and to ensure that the measuring tube is always filled with liquid.
6. The measuring tube, the outer casing, the shield wire of the lead wire, and the pipe at both ends of the
sensor must be reliably grounded, and must not be shared with the grounding of other electrical equipment. This is a special installation requirement for the electromagnetic flow
meter.