Float level switch selection considerations
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

brand information

Float level switch selection considerations

The float ball liquid level switch has a wide application range, various installation forms, and multi-point control passive components. Its performance is stable and reliable, and its anti-interference ability is strong. The structure is simple, the installation is convenient, and the maintenance cost is low. The float level switch is available in a variety of materials and is suitable for a wide range of applications. Related technical parameters:
Measuring range: 0 ~ 8000mm
**degree: ±10mm
Contact power: ≤70W
Control switch voltage: DC/AC220V, DC24V
Control contact life: 1 × 107 times
Working pressure: 1.6 MPa 2.5MPa
Working temperature: Standard type: -35~120°C
High temperature custom
Float material: F4, PP, 304, 304+F4
Medium density: 0.5~2.0g/cm3
Medium viscosity: ≤0.8Pa s 3Pa s
Connection: thread or flange
Wiring form: ordinary junction box or explosion-proof junction box or twisted wire
Shell protection: IP65
Its selection considerations:
The float level switch is divided into a fixed magnetic float level switch and an adjustable magnetic float level switch. When selecting a model of the magnetic float level switch, consider fixed or adjustable hysteresis, liquid density, mounting position and process connection. .