Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language:
∷
Industry new
How to install the ultrasonic flowmeter correctly
1. Observe whether the installation site pipeline meets the 5D after 10D in the straight pipe section and the distance from the pump 30D. (D is the inner diameter of the pipe)
2. Confirm the fluid medium in the ultrasonic flowmeter pipe and whether it is full.
3. Confirm the material of the pipe and the wall thickness (taking into account the scale of the inner wall of the pipe).
4. Confirm the service life of the pipeline. After using the pipeline for 10 years or so, even if it is made of carbon steel, the plug-in installation is also adopted.
5. After the first four steps are completed, you can confirm which sensor is installed.
6. Start entering parameters into the body to determine the installation distance.
7, very important: ****** test the installation distance.