How to install the intelligent radar level gauge correctly at the scene
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

brand information

How to install the intelligent radar level gauge correctly at the scene

How to install the intelligent radar level gauge correctly on site, and how to choose the correct installation location?

The standard installation of the intelligent radar level gauge includes: the marking should point to the tank wall, the installation marking should be located in the right half of the flange of the two screw holes; the orientation of the flange, in order to confirm the position, on the flange or turnbuckle All are marked, this tag must match when installed:
1. The fingering of the flange should point to the core of the tank wall or tank;
2. If using a waveguide installation, the flange mark should point to the side of the opening;
3. If using a bypass pipe installation, the flange mark should be on the side that points to the communication pipe;

In the application process of the intelligent radar level gauge, the amplitude of the echo signal indicates whether the installation position is the best. If the solid material should be used for the purpose, if the amplitude of the echo signal is low, the flange can be rotated, and each hole is rotated to make the interference echo. Minimize. Extra can also be stored through false echoes to achieve the best survey results;
     The steps are as follows:
(1) Before the process of opening the tank is connected, it must be clearly recognized that there is no pressure in the tank and there is no harmful medium;
(2) It should be clearly recognized that the empty tank or material level in the vessel should be positioned and debugged under the condition of covering the bottom of the tank. The positioning and debugging can also be carried out under the condition that the material level is small; the false level can be stored and the radar level can be Calculate the echo signal to optimize;
(3) Turn the flange mark to a hole position, or turn the turnbuckle by 1/8 turn, pay attention to the amplitude, and then rotate the flange or turnbuckle until it turns one turn to locate the best position of the echo signal. ;
(4) Fix the flange at the optimal position or tighten the turnbuckle. If it is indispensable, change it to seal tightly.

 

Dear Customer: Hello! Shanghai Shuozhou Electronic Technology Co., Ltd. is a high-quality development group with strong technical force. Your current page is a smart radar level meter product. If you are interested in this product, you can call our service hotline to learn more about the related products. We will do our best to serve you. The main products are: Position meter, RF admittance, pneumatic vibrator, etc.