Mass flowmeter to ensure accuracy method description
Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language: Chinese ∷  English
Search

brand information

Mass flowmeter to ensure accuracy method description

Today, with the rapid development of science and technology, all walks of life are constantly carrying out technological transformation, updating equipment, and producing high-precision mass flow meters. What are they doing for this? It goes without saying that they are all subtly doing one. Work, that is to reduce costs and increase production. So how do you make the mass flow meter work with high precision?

1. Selection: Firstly, the process flow should be determined during the selection, and then the diameter of the flowmeter should be selected according to the process flow. The upper limit of the process flow should not be less than 70% of the upper limit of the flowmeter design. This is the only way to ensure that the flowmeter is operating at its optimum condition. Thereby ensuring the accuracy of the flow meter. In addition, the diameter of the process pipeline must be consistent with the diameter of the flowmeter, otherwise it will bring errors.

2, the choice of mass flowmeter installation environment

a. The installation position of the mass flowmeter must be away from vibration sources and magnetic fields (such as large motors and large vibration sources).

b. The mass flow meter must be grounded. The flow signal generated by the sensor is very weak, usually in microvolts or millivolts, so preventing external electromagnetic interference is an important factor in the use of mass flowmeters.

c. The mass flowmeter should be installed on the pipeline without stress. The straight pipe sections before and after should be the first 10DN and the rear 5DN. There should be brackets on both sides of the mass flowmeter. And the mass flowmeter must also be equipped with a shut-off valve (for the purpose of disassembly and assembly and mass flowmeter zero adjustment).

After the mass flowmeter is normally put into use, first close the outlet valve, then close the inlet valve to see if the flowmeter indication is zero or zero, then the flowmeter is all normal, otherwise, find a professional verification personnel to make adjustments. After the flowmeter is calibrated, the parameter indicators must never be changed, otherwise the mass flow meter will be misaligned. The mass flow meter does not need to be adjusted in the normal installation.