Description of the meter's quantitative timing setting function
(1) Electromagnetic flowmeter cycle display function Some measurement objects are often observed in addition to flow. It is also necessary to observe fluid pressure and temperature frequently. The cyclic display function cyclically displays the cumulative flow rate, instantaneous flow rate 'fluid pressure, fluid temperature' at the specified switching time interval. It can also be specified as a fixed point display. (2) ‘time meter reading function The timed meter reading function reads the accumulated value of the flow according to the specified meter reading time (pre-set in the menu) and stores it in the meter. In the unit. When the meter reader presses the meter reading button, the meter displays the meter reading symbol and the data in the unit. The accumulated value in this unit is maintained until the next day “watch time” is refreshed. If the gold plant flow calculator sets the same meter reading time, the difference between the meter reading line and the time does not affect the transcription result, so it is beneficial to the balance calculation of the table and the total table. (3) 24h cumulative value display function. , r The meter stores the cumulative value of the traffic at the last 24 hours of the hour in the specified data area, and the user can access the button by operating the button according to the prescribed method. This feature provides a transparent and accurate means of accumulating values used in the transcript placement test. (4) Quantitative issue function This function includes the delivery quantity setting, advance quantity setting, starting, emergency stop, large valve opening and closing, small room opening and closing, etc., which is specially used for feeding, loading and barrel control. Self-diagnostic function The calculator can perform self-diagnosis according to a certain process. When the meter inputs: the signal or the internal signal is abnormal, the alarm light on the panel lights up, and the code or mnemonic is used to display the cause of the abnormality in a certain order. If the CPU itself is blocked, the CPU fault light on the panel lights up, and the relevant personnel are notified to handle it. Communication function The calculator can communicate with the host computer through its communication port. The communication protocol is generally RS-232C or RS-485, and the baud rate is also several files. The design should be selected according to the system requirements.