Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language:
∷
Industry new
How to verify the influence of Reynolds number Flowmeter offer Imported products
Example 1 known condition a. Fluid Name: Diesel b. Fluid temperature: 30 ° C c. Fluid density: P = 810kglm3 d. Fluid viscosity: u=0.0031Pa. s e. Pipe inner diameter: D = 0.05m f. Maximum flow: g,. . ; a 50 rri3/11 2 calculation a. Maximum mass flow qmrn. Calculation g. . . := Pq,. . :=11. 25kg/s b. Reynolds number ReDm at maximum flow rate. Calculation of [using equation (8.2)] 4 qmmax 4×11. 25 l×10 4 R has Dmax one - one one 9.2 2 7c D, u 7c×0.05×o. 0031 c. Calculation of volume flow g, i for each typical flow point qVz=Rq three ReD, (8.6) Substituting the Reynolds numbers of typical flow points in Table 8.2 into equations (8.6) The quantities q, ; are listed in Table 8.3. Figure 8.6 Calculating the correction factor online Block diagram 213 Table 8.3 Correction factors for each feature point ┃Flow value qY//(ma/h) ┃ Reynolds number ReDi ┃ Correction factor A ┃Flow value q,i/(rn3/11) ┃ ┃ 2. 976 ┃ 5.5×103 ┃ 0. 886 ┃ 10. 823 ┃ ┃ 4. 329 ┃ 8. O×103 ┃ 0. 935 ┃ 21. 645 ┃ ┃ 6. 494 ┃ 1.2×104 ┃ 0. 964 ┃ 50. 000 ┃ This method can be used to correct errors in low flow sections of liquids that have a higher viscosity than water.