German Baode flowmeter se30/8030 how to clean the introduction

How to clean the Baode flowmeter se30/8030
Baode flowmeter se30/8030 has high reliability, small maintenance and long-term stability of instrument parameters. With piezoelectric stress sensor, it has high reliability and can work in the operating temperature range of -20 °C ~ +250 °C. There are analog standard signals and digital pulse signal output, which is easy to use with digital systems such as computers. Baode flowmeter se30/8030 is a relatively advanced and ideal flow meter. The Bode Flowmeter se30/8030 is a fluid oscillating flowmeter based on the Karman vortex principle, which places a non-streamlined symmetrical shape object in the flowing fluid (the vortex generation is called vortex flow sensor). The body will produce two regular vortices on both sides of the downstream, that is, the vortex frequency of the Karman vortex street is proportional to the fluid velocity:
What are the characteristics of the Baode flowmeter se30/8030 when working:
1) The output signal is a pulse signal proportional to the flow rate. The Pod Flowmeter se30/8030 facilitates data processing and computer networking.
2) Wide range and high precision.
3) No moving parts, high reliability, simple structure, easy to install and maintain.
4) The detecting element is not in direct contact with the measured medium, and is not affected by the chemical properties of the fluid. The Baode flowmeter se30/8030 has a wide application range and long service life.
5) Baode flowmeter se30/8030 has strong anti-interference ability, easy to calculate flow, and is not affected by fluid physical properties, which brings convenience to the calibration and use of Baode flowmeter se30/8030.
How to clean the Baode flowmeter se30/8030:
Select the Pod flowmeter se30/8030 collar gently, remove the ring with a needle-nosed pliers, block the outlet of the measuring tube with your hand, slowly invert the measuring tube, feel the float slide out, and then take out. Clean the surface impurities with water, gas or a dry cloth, and clean the measuring tube together with the stopper ring. When finished, load the float into the measuring tube in the order of disassembly. The upper and lower guide rods of the float are all cylindrical. The float can be placed in the measuring tube and gently shaken to fall into the guide. However, it must be distinguished that the upper and lower sides of the float cannot be reversed; At the same place, align the flattened part with the groove of the guide, insert it, and then align the retaining ring with the guide rod on the float, and snap the collar into the groove. If the collar is too loose, Use your hands to gently pull the collar outward, but do not use excessive force. After all the assembly is completed, push the float to see the flexibility of the pointer rotation.
In the process of taking out the Bode flowmeter se30/8030 float and cleaning, pay attention to the float can not be dropped, knocked, smashed, etc., should be handled lightly and gently during the entire cleaning process to prevent the upper and lower distractions from being scrapped. Do not place the float close to the strong magnetic field, so as to avoid the polarity change of the float. When installing the ring, make sure that the collar falls into the collar groove to prevent the Bode flowmeter se30/8030 from being impacted by the measuring medium. The ring and the collar are detached and rushed into the pipe, causing damage to the valves and pumps at the rear end, causing unnecessary losses. The converter indicates that there is no moving part in the part, please do not open it when cleaning.