Welcome: KUNAG Fluid Control System (Shanghai) Co., Ltd.
Language:
∷
Industry new
Magnetic valve linker construction and technical performance
Solenoid valve connectors are widely used in sensors, testing instruments, electronic instrumentation, electronic machinery, communications, aviation, navigation, computers, LED lights, industrial automation, etc. This article details the basic composition of solenoid valves and technical performance. Related Information. Solenoid valve linker construction and technical performance First, the composition of the solenoid valve The solenoid valve connector consists of a plug and a socket. The plug is square and the socket is square and round. Second, the basic technical parameters 1, plug parameters: Number of stitches 2+PE/3+PE Locking method center screw Connection method Connection section mm2 0.34mm2 (min, AWG22) Cable diameter 6-8mm/8-10mm Enclosure protection class IP65 High temperature +120 ° C Low temperature -30 ° C Measuring current (40 ° C) 1A, 2A, 10A Housing Material PA (UL94HB) 2, socket parameters: Number of stitches 2+PE/3+PE Locking method center screw Connection method Connection section mm2 1.5mm2 (max, AWG16) Enclosure protection class IP65 High temperature +120 ° C Low temperature -30 ° C Measuring current (40 ° C) 1A, 2A, 10A Cable plug housing PA (UL94HB) Third, the application area Solenoid valve connectors are widely used in sensors, testing instruments, electronic instrumentation, electronic machinery, communications, aviation, navigation, computers, LED lights, industrial automation and other fields (Guangzhou (Yueguo) Panyu is a manufacturer of solenoid valve connectors) Fourth, the life test of the solenoid valve 4 situations that hinder the normal operation of the solenoid valve and shorten the life: 1. The medium changes during use. 2, rust inside the takeover 3. The oil of the air compressor is oxidized, and carbon tar and other impurities are generated and mixed into the pipeline. 4. There are dust, dirt and other impurities in the pipeline. V. Technical performance and indicators: (1) The water valve is at a constant pressure of 12 bar (can be set) and passes hot water up to 90 °C. According to different types of water valve on-off requirements (such as 5s pass 5s off once), the number of consecutive tests is about 50,000 times (can be set). (2) The test bench can automatically record the on-off condition of the water valve coil. The faulty water valve can be recorded in the middle, and the stop time can be recorded, but it does not affect the operation of other water valves. (3) The test bench can meet the simultaneous detection of 10 water valves. (4) Pressure control accuracy ± 0.2 bar, water temperature control accuracy is ± 1 ° C. (5) The solenoid valve voltage is adjustable (12~300V), (6) Can be used as a low-voltage on-off performance test.