Electromagnetic flowmeter application introduction
The measuring principle of ABGD electromagnetic flow
meter is Faraday's law of electromagnetic induction. The important components of the
sensor are: measuring tube, electrode, excitation
coil, iron core and yoke housing. It is important for measuring the volumetric flow in conductive liquids and slurries in solid pipes. It contains strong enough liquids such as acid, alkali and salt. Most of the products are used in petroleum, chemical, metallurgy, textile, food, pharmaceutical, paper and other industries as well as environmental protection, municipal governance, water conservancy and other areas. Electromagnetic flow
meter product features:
1. Measurements are not affected by changes in fluid density, viscosity, temperature, pressure, and
conductivity;
2. There is no obstructive flow component in the measuring tube, no pressure loss, and the straight tube section is low;
3, series nominal dia
meter DN15 ~ DN3000. Sensor lining and electrode data are available in a variety of options;
4, the converter accepts the contemporary excitation method, low power consumption, zero point and high precision. The flow range can reach 1500:1;
5. The changer can be integrated with the
sensor or can be resolved;
6, the converter accepts 16-bit high-performance micro-processor, 2x16LCD display, para
meter setting and saving, programming is sturdy;
7. The flow
meter is a two-way measurement system with three totalizers: positive total, reverse total and total difference; can be displayed. Zhuang, anti-flow, and abundance of multiple outputs: electricity
Stream, pulse, digital communication, HART;
8. The changer accepts face building skills (SMT), abundance self-test and self-diagnosis;